New pages
- 09:56, 9 January 2024 HASP Error (502): Logging in twice to the same object. (hist) [537 bytes] Ted.dannevig (talk | contribs) (Created page) (Tag: Visual edit)
- 15:42, 5 January 2024 HASP Error (31): Feature not found (hist) [381 bytes] Jberthold (talk | contribs) (Created page with "This is typical of misleading error messages from the OLI security system. The actual error is rare and occurs only in the following situations: # A full stand-alone version...")
- 14:40, 3 January 2024 Named User FAQ (hist) [4,361 bytes] Jberthold (talk | contribs) (Created page with "Frequently Asked Questions (FAQ) about OLI's Named User license model. ==Named user administration== ;How will OLI track Named Users? :When you agree to license OLI Software...")
- 11:11, 28 November 2023 The serial number specified is invalid or has expired. The installation cannot continue and will now exit (hist) [850 bytes] Jberthold (talk | contribs) (Created page with "If the following error message occurs when installing the OLI software... File:BeyondTrustError.png Note: Our example is for OLI Studio but it applies to all OLI install...")
- 11:29, 7 September 2023 How to enable the optional calculations in OLI Studio (hist) [210 bytes] Jberthold (talk | contribs) (Created page with "This video shows you how to enable the optional calculations, such as Gibbs Free Energy and Entropy, in OLI Studio. {{#ev:youtube|sLePU1yuuik}} Category: Videos Catego...")
- 08:19, 23 August 2023 Exporting a DBS file from OLI Flowsheet (hist) [705 bytes] Jberthold (talk | contribs) (Created page with "Sometimes a DBS file created in OLI Flowsheet will be needed in other OLI-related programs. For example, OLI Studio can use a prebuilt DBS file. You will first need to create...")
- 06:52, 29 June 2023 Video Tips (hist) [121 bytes] Jberthold (talk | contribs) (Created page with "== Modifying the solids in a simulation == {{#ev:youtube|qHxaFPJ8hfM}} Category: Videos")
- 12:03, 16 June 2023 Does Ferric Hydroxide - Fe(OH)3 exist and why does OLI model it (hist) [1,821 bytes] Sean.chambers (talk | contribs) (Created page with "'''A question was raised by a user:''' ''I have always questions, probably because my knowledge of inorganic chemistry is superficial. I read in the book "De la solution à l...")
- 12:02, 16 June 2023 How to "Set" the partial pressure of a gas (hist) [6,706 bytes] Sean.chambers (talk | contribs) (Created page with "How do you set the partial pressure of a gas in OLI Studio? The short is answer is that you cannot. OK, now for the real answer. You can "Set" the partial pressure of a ga...")
- 12:02, 16 June 2023 How much of a solid will form (hist) [4,405 bytes] Sean.chambers (talk | contribs) (Created page with " == How does the OLI Software determine how much solid will form? == To begin this discussion we will assume we have a simple solution of CaCO<sub>3</sub> and H<sub>2</sub>O...")
- 12:01, 16 June 2023 The Difference between Scaling Tendency and Pre-scaling Tendency (hist) [4,733 bytes] Sean.chambers (talk | contribs) (Created page with "== Introduction == What is the difference between a scaling tendency and a pre-scaling tendency? Many users are confused by what OLI means by a scaling tendency and a pre-sca...")
- 12:01, 16 June 2023 My trial period has ended, now what (hist) [788 bytes] Sean.chambers (talk | contribs) (Created page with "The trial period given by OLI Systems, Inc. is 30 days from the date of installation. No extensions are possible given the trial locking software that OLI uses. Please conta...")
- 12:00, 16 June 2023 Was a trial software ever installed on my computer (hist) [2,173 bytes] Sean.chambers (talk | contribs) (Created page with " == How to determine if any trial software from OLI Systems was ever installed on your computer? == The trial software lock program that OLI uses permits only one instance of...")
- 11:59, 16 June 2023 ScaleChem: Studio or Standard (hist) [3,360 bytes] Sean.chambers (talk | contribs) (Created page with "OLI Studio: ScaleChem is software developed in conjunction with OLI's Produced Water Group consortium, and released in December 2012. OLI Studio: ScaleChem is a new product an...")
- 12:45, 30 May 2023 Why is the Gibbs Free Energy of Formation for the Hydrogen Ion not zero (hist) [1,353 bytes] Sean.chambers (talk | contribs) (Created page with "OLI has been predicting the Gibbs Free Energy of Formation of species for some time and can report them from the software. For OLI Studio click here to see how to do that '''[...")
- 12:44, 30 May 2023 Why is H2O missing from a composition survey (hist) [391 bytes] Sean.chambers (talk | contribs) (Created page with "Why is H2O missing from a composition survey? Using concentration units such as mg/L will confuse the OLI Studio program if you also attempt to vary it in a composition surve...")
- 12:43, 30 May 2023 Why is Carbonic Acid not in any OLI Databases (hist) [868 bytes] Sean.chambers (talk | contribs) (Created page with " == Question: Why is carbonic acid (H<sub>2</sub>CO<sub>3</sub>) not in any OLI database? == OLI has not introduced H<sub>2</sub>CO<sub>3(aq)</sub> as a separate species; ins...")
- 12:43, 30 May 2023 Why are my ion concentrations larger in the aqueous phase column than in the total column (hist) [1,433 bytes] Sean.chambers (talk | contribs) (Created page with "A user reported that the ion concentration in a report are larger in the aqueous phase column than in the total column. Why is that? The problem here is perception. The resu...")
- 12:40, 30 May 2023 Why do you have to update the client serial number (hist) [4,169 bytes] Sean.chambers (talk | contribs) (Created page with "A frequent question from IT administrators is why does OLI provide a new client serial number for each new server serial number? When a network license is due for renewal (us...") (Tag: Visual edit: Switched)
- 07:45, 6 March 2023 What's the difference between Thermodynamic Frameworks (hist) [1,074 bytes] DMILLER (talk | contribs) (Created page with "The limits are thermodynamic framework dependent. There are three frameworks available in OLI Software. MSE (default in version 11.5), MSE-SRK, and AQ. For '''MSE''' the...") (Tag: Visual edit)
- 07:43, 6 March 2023 What's the difference between Thermodynamic Frameworks? AQ, MSE vs MSE-SRK? (hist) [957 bytes] DMILLER (talk | contribs) (Created page with "The limits are thermodynamic framework dependent. There are three frameworks available in OLI Software. MSE (default in version 11.5), MSE-SRK, and AQ. 1. For '''MSE''' the...")
- 10:15, 7 February 2023 Thermophysical Modeling: Why was UREA modified for the MSE model (hist) [3,275 bytes] Jberthold (talk | contribs) (Created page with " == The Background == Circa 2009 OLI Systems was asked by one of its customers to model the decomposition of Urea in aqueous solutions. OLI undertook this modeling and crea...")
- 10:54, 30 January 2023 Did OLI regress your data system (hist) [363 bytes] Jberthold (talk | contribs) (Created page with "How do you know if OLI regressed your data system? Our interaction matrix feature in OLI Studio can give you an idea of we covered the binary systems that comprise your data s...")
- 14:41, 25 January 2023 How is pH calculated when there is no H ion (hist) [1,770 bytes] Jberthold (talk | contribs) (Created page with "==How pH is calculated in the Mole Fraction based concentration basis== ===Overview=== The new mole fraction based concentration basis available in the OLI software (ESP v...")
- 07:41, 18 January 2023 The differences between Standard Volume, Standard Liquid Volume, and Volume (hist) [64 bytes] Jberthold (talk | contribs) (Created page with "See Volumes vs. Standard Volumes vs. Standard Liquid Volumes")
- 08:47, 2 December 2022 PIPESIM Interface (hist) [689 bytes] Jberthold (talk | contribs) (Created page with "The OLI Studio - PIPESIM interface is a text file called a PVT file. This file was then imported into PIPESIM. As of 2020 OLI no longer has an agreement with Schlumberger (th...")
- 21:03, 10 November 2022 Entering Bromley-Zemaitis interaction parameters (hist) [143 bytes] Jberthold (talk | contribs) (Added a video) (Tag: Visual edit)
- 10:05, 24 October 2022 Frequently Asked Questions about Scaling Inhibition (hist) [1,100 bytes] Jberthold (talk | contribs) (Created page with "== What does '''n/a''' mean in the report? == Question: Sometimes in a calculation output, the tag "'''n/a'''" will appear such as in the following example. What does this me...")
- 08:14, 21 September 2022 OLI Flowsheet Reset Layout (hist) [601 bytes] Jberthold (talk | contribs) (Created page with "How to reset the layout of OLI Flowsheet? Sometimes you will accidently click a close button and you lost a panal in OLI flowsheet. That is what has happened in this image, t...")
- 08:41, 19 September 2022 Scale Inhibition (hist) [4,763 bytes] Jberthold (talk | contribs) (Created page with "== What is scaling induction time? == One of the premier issues in the oil and gas industry is scale deposition which occurs due to changes in process conditions, such as pre...") originally created as "Scaling Induction Time / Scaling Inhibition"