Using OLI Databanks in Unisim Design

From wiki.olisystems.com
Revision as of 07:46, 16 March 2020 by Jberthold (talk | contribs) (Assumptions)
Jump to: navigation, search

Introduction

Many times new or updated data is available from OLI Systems, Inc. When this occurs, a private (or user) databank is distributed. These private databanks are distributed as two (2) files. The files will have the extensions of DDB and DIC. Both files need to reside in the same folder. OLI recommends the following local folder:

\Documents\My OLI Cases\Databanks

OLI now uses this folder as its default folder. Please copy both the supplied DDB and DIC file to this folder.

Assumptions

• It is assumed that you have Unisim Design and that you have the Alliance Suite for Unisim Design installed.

• This tip assumes you are already familiar with Unisim Design and can access the component views.

Accessing the OLI User Supplied Databank

Step 1: Select the Simulation Basis Manager. This will display the Components tab.

2015-08-19 11-55-28.png

Click on the Fluid Pkgs tab

Step 2: You now need to add a fluid package.

2015-08-19 11-56-52.png

Click the Add Button.

Step 3: Scroll down the list of Property Packages till you find OLI Electrolyte. The dialog will expand to show additional fields.

2015-08-19 11-58-17.png

Choose your thermodynamic framework, the default is the Aqueous Electrolyte (AE). Change to the Mixed-Solvent Electrolyte (MSE) if desired. For this example we will choose the MSE Framework.

Step 4: Click on the “x” to close this window. You will be returned to the current fluid packages window. Highlight the OLI Electrolyte line and then click the Components tab.

2015-08-19 12-06-07.png

Step 5: A new component list will appear. High light the new component list and then click the View button.

2015-08-19 12-07-27.png

Step 6: Two types of components will be displayed in the Components tree. Select Electrolyte. The window will expand to display more components. Click the Full radio button. The Additional Databank button should be visible. Click the button.

2015-08-19 12-08-32.png

There are two radio buttons just below the Additional Databank button. The button AE selects the traditional Aqueous Electrolyte thermodynamic framework (default) and the MSE button selects the Mixed-solvent- Electrolyte thermodynamic framework. When you switch frameworks, you will only have access to databases created in the same framework. Otherwise a mis-match in data will occur. In our example the MSE button has been selected.

2015-08-19 12-11-41.png

Step 7: The procedure that works well is to first specify the path (or location) of the private database. In this example the database we want to use is:

C:\Users\jberthold.OFFICE\Documents\My OLI Cases\Technical Support\OLI\12845\esp2

(remember, your path will be different)

2015-08-19 12-13-17.png

Once you have entered the path, and it is accepted. Enter the name of the private database in the field. Here we have entered the name CRUDE.

2015-08-19 12-14-19.png

This must be a valid ESP format database. Finally we have checked the box to use this database. The Unisim Design program will indicate that it is reading a pure component database.

2015-08-19 12-15-40.png

The program is now ready to use the new OLI database.

Author: Jim Berthold