== Standards ==
+
== ISO Corrosion standards ==
  
Comparison with ISO15156
+
Comparison with ISO15156.
 +
 
 +
ISO15156 is a standard for corrosion-resistant alloy selection for Oil and Gas production.
  
 
The environmental limits for the alloys in ISO15156-3 are based on experimental data with chloride concentration up to 180000 mg/l using NaCl.
 
The environmental limits for the alloys in ISO15156-3 are based on experimental data with chloride concentration up to 180000 mg/l using NaCl.
Line 21: Line 23:
 
[[File:ISO.png]]
 
[[File:ISO.png]]
  
Plot Analysis: The transition to localized corrosion is predicted at about 50 psi H2S in OLI's predictive model, whereas ISO 15156 predicts that the alloy is OK up to 200 psi H2S. So, the electrochemical model is more conservative than the standard. But the transition would move to a substantially higher P(H2S) if we lowered the chloride concentration (because Erp strongly depends on Cl).  
+
Plot Analysis: The transition to localized corrosion is predicted at about 50 psi H2S in OLI's predictive model, whereas ISO 15156 predicts that the alloy is OK up to 200 psi H2S. The electrochemical model is more conservative than the standard. But the transition would move to a substantially higher P(H2S) if the chloride concentration is lowered(because Erp strongly depends on Cl).  
 
The driving force for localized corrosion, i.e., the difference between Ecorr and Erp in the plot above is small, i.e., it is only about 50 mV at 200 psi H2S, which is within the experimental uncertainty.
 
The driving force for localized corrosion, i.e., the difference between Ecorr and Erp in the plot above is small, i.e., it is only about 50 mV at 200 psi H2S, which is within the experimental uncertainty.
 +
 +
Note: The above mentioned results are still under development at OLI.

Revision as of 10:25, 12 May 2017

Frequently Asked Questions about OLI and Corrosion

Databanks

When standard database predicts precipitation of Fe(III), Zn(II), Cu(II) as Fe(OH)3, Zn(OH)2 and Cu(OH)2 respectively, Inclusion of the Corrosion database produces the more stable hematite Fe2O3, goethite FeO(OH), ZnO and CuO solids


Phenomena

Elemental Sulfur Corrosion

ISO Corrosion standards

Comparison with ISO15156.

ISO15156 is a standard for corrosion-resistant alloy selection for Oil and Gas production.

The environmental limits for the alloys in ISO15156-3 are based on experimental data with chloride concentration up to 180000 mg/l using NaCl.

A plot for Ecorr and Erp at 150 C and 5.7 m NaCl (180000 mg Cl/l) with varying partial pressure of H2S using OLI:


ISO.png

Plot Analysis: The transition to localized corrosion is predicted at about 50 psi H2S in OLI's predictive model, whereas ISO 15156 predicts that the alloy is OK up to 200 psi H2S. The electrochemical model is more conservative than the standard. But the transition would move to a substantially higher P(H2S) if the chloride concentration is lowered(because Erp strongly depends on Cl). The driving force for localized corrosion, i.e., the difference between Ecorr and Erp in the plot above is small, i.e., it is only about 50 mV at 200 psi H2S, which is within the experimental uncertainty.

Note: The above mentioned results are still under development at OLI.