Difference between revisions of "Current issues with OLI Flowsheet: ESP (Beta)"
Line 3: | Line 3: | ||
− | == Unit Operations | + | == Unit Operations == |
+ | |||
+ | === Current Support Status === | ||
There are many unit operations in the ESP Original program. Most have been or will be implemented in OLI Flowsheet: ESP. Some unit operations are not yet ready but are planned for inclusion. Other unit operations are not planned for inclusion in the software since OLI's business interests have migrated away from those areas. | There are many unit operations in the ESP Original program. Most have been or will be implemented in OLI Flowsheet: ESP. Some unit operations are not yet ready but are planned for inclusion. Other unit operations are not planned for inclusion in the software since OLI's business interests have migrated away from those areas. | ||
Line 90: | Line 92: | ||
| Xcrystallizer || NO || NO || NO | | Xcrystallizer || NO || NO || NO | ||
|} | |} | ||
+ | |||
+ | |||
+ | === Specific Unit Operation Development Notes === | ||
+ | |||
+ | ; Unit Operation Notes | ||
+ | ; Controllers : Not all controller parameters are supported | ||
+ | |||
+ | == User Interface Issues == | ||
+ | |||
+ | === Linking to other OLI Programs === | ||
+ | |||
+ | ==== Linking to OLI Studio/Analyzers ==== | ||
+ | ; Copy and Paste : Not yet implemented | ||
+ | |||
+ | ==== Import from ESP ==== | ||
+ | ; Importing supported : Some blocks not yet implemented will fail to open. | ||
+ | |||
+ | === Reports === | ||
+ | |||
+ | ==== Missing or incomplete Reports ==== | ||
+ | ; Packed columns : Incomplete data. All data is available from the solver but is not yet captures | ||
+ | ; Stream : Surface Tension, interfacial tension and ionic strength are currently not reported | ||
+ | |||
Revision as of 12:29, 26 April 2016
Here are some of the known issues with the OLI Flowsheet: ESP (Beta) program.
Contents
Unit Operations
Current Support Status
There are many unit operations in the ESP Original program. Most have been or will be implemented in OLI Flowsheet: ESP. Some unit operations are not yet ready but are planned for inclusion. Other unit operations are not planned for inclusion in the software since OLI's business interests have migrated away from those areas.
These undeveloped unit operations will continue to be supported in the ESP Original program.
Those unit operations in the third column Future Development which are blank are planned for inclusion but have not yet been scheduled for development.
ESP Original Unit Operation | Currently Supported in OLI Flowsheet:ESP | Under development | Future Development |
---|---|---|---|
Absorber - Equilibrium | YES | ||
Absorber - Mass Transfer | YES | ||
Activated Sludge Bioreactor | NO | NO | NO |
Calculator | NO | YES | |
Clarifier | NO | NO | NO |
Compressor | YES | ||
Crystallizer | NO | NO | |
Dehydrator | NO | NO | |
Electrodialysis | NO | NO | |
Electrolyzer | NO | NO | |
Energy Transfer | YES | ||
Extractor | NO | NO | NO |
Feedback Controller | YES | ||
Feedfoward Controller | YES | ||
Filter | NO | NO | |
Heat Exhanger | YES | ||
Incinerator | NO | NO | NO |
Manipulate | YES | ||
Membrane | NO | YES | |
Mix | YES | ||
MSMPR Crystallizer | YES | NO | NO |
Pump | YES | YES | |
Reactor - Aqueous | YES | ||
Reactor - Aqueous Mass Transfer | NO | YES | |
Reactor - Bio | NO | NO | NO |
Reactor - Gibbs | YES | ||
Reactor - Non-Aqueous | NO | NO | NO |
Saturator | NO | NO | |
Sensitivity | NO | YES | |
Sepearate | YES | ||
Settler | NO | NO | |
Split - Component | YES | ||
Split - Flow | YES | ||
Stripper - Equilibrium | YES | ||
Stripper - Mass Transfer | YES | ||
Turbine | YES | ||
User Block | YES | NO | NO |
Xcrystallizer | NO | NO | NO |
Specific Unit Operation Development Notes
- Unit Operation Notes
- Controllers
- Not all controller parameters are supported
User Interface Issues
Linking to other OLI Programs
Linking to OLI Studio/Analyzers
- Copy and Paste
- Not yet implemented
Import from ESP
- Importing supported
- Some blocks not yet implemented will fail to open.
Reports
Missing or incomplete Reports
- Packed columns
- Incomplete data. All data is available from the solver but is not yet captures
- Stream
- Surface Tension, interfacial tension and ionic strength are currently not reported
Operating Systems Supported
All operating systems from Microsoft Windows Vista and later are supported. Microsoft Windows XP and earlier are not supported.