Select Solids and turn on Scaling Tendencies

From wiki.olisystems.com
Jump to: navigation, search


How to Select Solids and turn on Scaling Tendencies?

You can eliminate solids from the chemistry if you want to speed up the calculation or to prevent a solid that is known not to form. You can obtain a scaling tendency for the eliminated solid if you so require.

First, enter some chemistry into the grid. In our example we are entering calcium carbonate, magnesium carbonate and sodium chloride

1.PNG

Select Chemistry from the menu items.

2.PNG

This will display a list of choices.


Choose Model options. Click on Phases Tab

3.PNG

By default, the OLI/Analyzer will consider an aqueous phase, a vapor phase and multiple solid phases. The solid phases considered are based on the input values chosen above.

To specify specific solids, click the Include Solid Phases check boxes.



A list of solid phases will be displayed. Placing a check mark next to each solid will remove the solid from consideration. If the “Consider Scaling Tendencies….” Check box is selected, then a Scaling tendency for the solid will be calculated but the solid will not be allowed to form regardless of the scaling tendency value.

If you have eliminated selected solids phases, a message will be displayed in the Summary box to remind you. ( E.g.: Excluding 10 solid phases displayed in the summary box below)

4.PNG



The simplest way to turn solids on or off in the latest version of Studio Analyzer is by clicking the solids button on the toolbar at the top of the software.

5.PNG


This was OLITips04