Corrosion rate calculation FAQ's
- How the effects of a passivation layer are included in the calculation of the generalized corrosion rate?
Passivation is included in the general corrosion rate model, see paper below:
“General corrosion model.pdf,” section “Active-Passive Transition,” for a description of how the passive layer is modeled. Then, the Applications section describes how this model reproduces selected experimental data.