Water Analyses contain elements, B, Si, S, and P

From wiki.olisystems.com
Revision as of 13:59, 29 July 2014 by AJGERBINO (talk | contribs) (Created page with "Water analysis data obtained from ICP measurements will contain concentrations for non metals like B, P, S, and Si. These elements do not exist in the water, rather they exi...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Water analysis data obtained from ICP measurements will contain concentrations for non metals like B, P, S, and Si. These elements do not exist in the water, rather they exist as dissolved ions. if you see these elements in the analysis, then you need to convert them to the following

Table 1 Converting element concentration to species for Brine or Water Analysis

ICP data Aqueous Species Formula to enter Formula weight multiplier
B, boron boric acid H3BO3 B (mg/l) * 5.71 = H3BO3 (mg/l)
Si, Silicon silica SiO2 Si (mg/l) * 2.14 = SiO2 (mg/l)
P, Phosphorus..... dihydrogen phosphate..... H2PO4-1 P (mg/l) * 3.13 = H2PO4 (mg/l)
S, Sulfur sulfate or sulfide HS-1 or SO4-2 (cannot tell from total S only).... S (mg/l) * 1.03 for HS-1 (mg/l) or
S (mg/l) * 3.0 for SO4-2 (mg/l)